While fires are lit in a boiler, in terms of uptake dampers and air register doors, what conditions must be met?
A
All uptake dampers should be locked open, all air register doors on lit burners should be wide open or throttled, and all air register doors on idle burners should be closed.
B
All uptake dampers should be locked open, all air register doors on lit burners should be throttled according to the firing rate, and all air register doors on idle burners should be open.
C
All uptake dampers should be throttled according to the firing rate, all air register doors on lit burners should be wide open, and all air register doors on idle burners should be closed.
D
All uptake dampers should be throttled according to the firing rate, all air register doors on lit burners should be throttled according to the firing rate, and all air register doors on idle burners should be closed.