The following information was recorded after a recent L.P. turbine bearing installation. The bearing temperature was logged at the indicated time intervals as: 1200-110°F (43°C)1210-123°F (51°C)1220-136°F (58°C)1230-149°F (65°C)1240-153°F (67°C)1250-155°F (68°C)1300-155°F (68°C) The shaft RPM and lube oil cooler outlet temperature remained constant. The readings indicate __________.
The following information was recorded after a recent L.P. turbine bearing installation. The bearing temperature was logged at the indicated time intervals as: 1200-110°F (43°C)1210-123°F (51°C)1220-136°F (58°C)1230-149°F (65°C)1240-153°F (67°C)1250-155°F (68°C)1300-155°F (68°C) The shaft RPM and lube oil cooler outlet temperature remained constant. The readings indicate __________.