During maneuvering on a steam vessel, the condenser vacuum begins to decrease when the turbines are slowed for a slow ahead bell. Which of the following should be checked?
A
The main circulating pump to ensure flow is not excessive.
B
The turbine gland seal steam to ensure proper pressure.
C
The air ejector to ensure the steam flow is not excessive.
D
The condensate pump to ensure the recirculation valve is closed.
Loading interactive features...
Question 1 / 2066636ef128f7522a1c52166f
Question 1 of 2066636ef128f7522a1c52166f
During maneuvering on a steam vessel, the condenser vacuum begins to decrease when the turbines are slowed for a slow ahead bell. Which of the following should be checked?